- ACellsसेल
- BPotential gradientsविभव प्रवणता
- CA condition of no current flow through the galvanometerगैल्वेनोमीटर से कोई धारा प्रवाहित न होने की स्थिति
- DA combination of cells, galvanometer and resistancesसेलों, गैल्वेनोमीटर तथा प्रतिरोधों का संयोजन
Show answer
Concept: A potentiometer is a null-deflection method: at the balance point no current is drawn from the cell being measured.
- At balance, the galvanometer shows zero deflection, so the test cell supplies no current.
- With zero current there is no drop across the internal resistance, so the reading equals the true emf (not the terminal voltage).
- (A), (B) and (D) are parts/ingredients of every such circuit (a voltmeter set-up also has them); they are not the reason for its accuracy.
Short trick: Accuracy of potentiometer = "null method" = zero current through galvanometer at balance.
Answer: (C) A condition of no current flow through the galvanometer
अवधारणा: विभवमापी एक शून्य-विक्षेप (null) विधि है: संतुलन बिंदु पर मापे जाने वाले सेल से कोई धारा नहीं ली जाती।
- संतुलन पर गैल्वेनोमीटर में शून्य विक्षेप होता है, अतः परीक्षण सेल कोई धारा नहीं देता।
- धारा शून्य होने से आंतरिक प्रतिरोध पर कोई विभवपात नहीं होता, अतः पाठ्यांक वास्तविक emf के बराबर होता है (टर्मिनल वोल्टता नहीं)।
- (A), (B) व (D) तो हर ऐसे परिपथ के भाग हैं (वोल्टमीटर व्यवस्था में भी होते हैं); ये इसकी यथार्थता का कारण नहीं हैं।
शॉर्ट ट्रिक: विभवमापी की यथार्थता = "शून्य विधि" = संतुलन पर गैल्वेनोमीटर से शून्य धारा।
उत्तर: (C) गैल्वेनोमीटर से कोई धारा प्रवाहित न होने की स्थिति